Products

1MD02 Series

Series of miniature thermoelectric modules for telecommunication applications
About the 1MD02 Series

The 1MD02 series consists of a range of standard single stage thermoelectric modules characterized by thermoelectric element dimensions of 0.2x0.2 mm and minimum element spacing. This allowed to achieve a placement density of 1100 elements per 1 cm2. The 1MD02 series is recommended for telecommunication applications where low operating current and low power consumption are required.

  • The minimum module size is 1x1.6 mm;

  • Minimum module thickness 0.6 mm;

  • All available options for Ferrotec-RMT thermoelectric modules;

  • Applications: telecommunications, photonics, heat flux sensors.
Specification

Specification is given at 300K, vacuum.

ABOUT THE MODULE

Appearance Type dTmax K Qmax W Imax A Umax V ACROhm H mm A mm B mm C mm D mm Datasheet
1MD02-004-XX (N=4)
1MD02-004-03 74 0.21 0.74 0.5
0.57 0.9 1.0 1.0 1.0 1.6
1MD02-004-04 75 0.16 0.55 0.76 1.0
1MD02-008-XX (N=8)

1MD02-008-03
74 0.42 0.74
1.0
1.14 0.9 1.2   1.2   1.9   1.2
1MD02-008-04
75 0.32 0.55 1.515 1.0
1MD02-008-05
76 0.26 0.44 1.89 1.1   
1MD02-012-XX (N=12)
1MD02-012-03
74 0.63 0.74 1.5
 
1.7 0.9 1.5   1.6   1.5   2.3  
1MD02-012-04
75 0.47 0.55 2.27 1.0
1MD02-012-05
76 0.38 0.44 2.84 1.1
1MD02-012-XX/1 (N=12)
1MD02-012-03/1
74 0.63 0.73
1.5  
1.7 0.9 1.2    1.9 1.2 2.3
1MD02-012-04/1
75 0.47 0.55 2.27 1.0
1MD02-012-05/1 76 0.38 0.44 2.84 1.1
1MD02-014-XX (N=14)

1MD02-014-03 74 0.73 0.73 1.8 1.99 0.9 1.2 2.1 1.2 2.6
1MD02-014-04 75 0.55 0.55 2.65 1.0
1MD02-014-05 76 0.44 0.44 3.31 1.1
1MD02-016-XX (N=16)
1MD02-016-03
74 0.84 0.73 2.0 2.27 0.9 1.3 2.4 1.3 3.1
1MD02-016-04 75 0.63 0.55 3.03 1.0
1MD02-016-05 76 0.51 0.44 3.78 1.1
1MD02-020-XX (N=20)
1MD02-020-03
74 1.04 0.73 2.5 2.84 0.9 1.3 3.0 1.3 3.6
1MD02-020-04 75 0.79 0.55 3.78 1.0
1MD02-020-05 76 0.63 0.44 4.73 1.1
1MD02-024-XX (N=24)
1MD02-024-03 74 1.25 0.73 3.0 3.41 0.9 2.1 2.1 2.1 2.7
1MD02-024-04 75 0.94 0.55 4.54 1.0
1MD02-024-05 76 0.76 0.44 5.67 1.1
1MD02-040-XX (N=40)
1MD02-040-03 74 2.08 0.73 5.0 5.68 0.9 2.4 3.2 2.4 4.0
1MD02-040-04 75 1.57 0.55 7.57 1.0
1MD02-040-05 76 1.26 0.44 9.45 1.1
1MD02-040-XX/1 (N=40)
1MD02-040-03/1 74 2.08 0.73 5.0 5.68 0.9 2.7 2.7 2.7 4.0
1MD02-040-04/1 75 1.57 0.55 7.57 1.0
1MD02-040-05/1 76 1.26 0.44 9.45 1.1
Telecommunications
Application
Read more
Application recommendations
Application recommendations
Read more